- Name
- Standalone Relay 1-Pole
- Brand
- SE Devices
- Features
- Feature Values Switch Load Capacity Watts
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x1013
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 30 FW: 3.00:03.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.71.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x024F
- Product type id
- 0x0003
- Long description
- The Standalone 1-Pole Relay is exclusively Z-Wave controllable, and designed to handle loads up to 3000W and be concealed inside Wall Boxes. The Relay can be used to switch both Heat Sources and Light fixtures. The product also contains a fail-safe mechanism which will switch the relay ON and OFF at fixed intervals, in case communication from a controlling device is lost. The Relay measures the immediate and accumulated power consumption of an attached load, which is reported at fixed intervals.
- Hardware platform
- ZM5202
- Short description
- Z-Wave controllable Standalone 1-Pole Relay (3000W) designed to be concealed in wall boxes.
- Product identifier
- AR1P
- Countries / regions
- European Union
- Certification number
- ZC10-18046093
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Power
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value 3000 neutral wire required electric load type value incandescent fluorescent mlv (magnetic) led inductive (e.g. motor) firmware updatable value updatable by professional/technician switch load capacity current value 13.1 supported meter type value electric energy sensors value power voltage current association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- From to description 0 32767 safety activation delay 5 safety off period the number of seconds to stay in off mode when safety is activated. the back unit turns on when the timer have elapsed. if value is 0, the back unit will not turn back on. the max limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) 0 2 0 0 600 from to description 0 32767 safety off period 6 safety on period the number of seconds to stay in on mode when safety is activated. the back unit turns back off when the timer have elapsed (and continues to turn on and off alternately). if value is 0, the back unit will not turn on at all. the max limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) 0 2 0 0 300 from to description 0 32767 safety on period texts
- ID Description Value 5