- Name
- Siterwell Power plug Sensor
- Brand
- Siterwell Technology
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0350
- Device type
- On/Off Power Switch
- Oem version
- HW: 65 FW: 3.70
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0266
- Product type id
- 0x0003
- Long description
- This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations. This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cut‐off.
- Hardware platform
- ZM5202
- Short description
- Smart power plug can control the on/off of electric appliance on mobile app. detect the current, voltage, accumulated voltage and offer overload protection.
- Product identifier
- STW-W3350WU
- Countries / regions
- European Union
- Certification number
- ZC10-17085749
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 9
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value white switch load capacity volt ampere value 12 a 230 v supported meter type value electric energy switch type value push button supported notification types value power management firmware updatable value updatable by manufacturer association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 65535 minutes 0 0 6 meter reporting setting this parameter defines by how much current changed must change to be reported to the z‐wave controller or z‐wave gateway, in percents. if the rate of current change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to z‐wave controller or z‐wave gateway. 0 1 0 0 5 from to description 1 100 % 0 0 8 time switch configure this parameter defines the timer function enable/disable. this parameter can be configured with 0 or 1, where 0 means disable time switch function and 1 enable. the time period will be defined in parameter #9. if this parameter is set to 1, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. 0 1 0 0 0 from to description 0 0 time switch disable 1 1 time switch enable 10 enable button on/off this parameter defines the button on/off function is enabled or not on the top of the wall plug. this parameter can be configured 0 and 1. if this parameter is set to ‘1’, users can turn on and off the wall plug by pressing the button on the top of the wall plug. if this parameter is set to ‘0’, the wall plug cannot be turned on and off by pressing the button. 0 1 0 0 1 from to 0 0 1 1 1 meter report enable this parameter defines disable/enable meter report measure data to controller. 0 1 0 0 1 from to description 0 0 disable report 1 1 enable report 7 remember relay status this parameter defined the relay status if remember or not. if remembered, the plug will restore the relay status last power off when the plug supply power next time. 0 1 0 0 1 from to description 1 1 emember the relay status. 0 0 don’t remember, the relay will keep off when plug supply power 5 led enable/disable this parameter defines the led indication function on/off. this parameter can be configured with 0 or 1, where 0 means disable led indication function and will always be turn‐off, and 1 means enable led function. 0 1 0 0 1 from to 0 0 1 1 2 set report interval this parameter defines interval time (in seconds) that meter report data to main controller. 0 2 0 0 300 from to description 1 65535 s 0 0 texts