- Name
- Plug-in Switch Mini
- Brand
- Telldus
- Features
- Feature Values Switch Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0701
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0003
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0701
- Z wave version
- 6.71.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0176
- Product type id
- 0x0003
- Long description
- Smart Plug can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
- Hardware platform
- ZM5101
- Short description
- Control lighting and other electronic equipment up to 2300 W (resistive load). The device is designed with very thin edges, making it possible to use two devices side by side in most electical outlets.
- Product identifier
- TZWP-102
- Countries / regions
- European Union
- Certification number
- ZC10-18036072
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 100
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value push button z wave scene type value scene switch load capacity watts value 2300 supported meter type value electric energy firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 85 85 setting the parameters 101~104 to the default value. 101 setting time for sending meter report (watt) the interval time of sending meter report (watt) to associated device (group lifeline). 0 4 0 0 600 from to description 0 0 the function is disabled. 5 2678400 available settings 102 setting time for sending meter report (kwh) the interval of sending meter report (kwh) to association device (group lifeline). 0 4 0 0 3600 from to description 0 0 the function is disabled. 5 2678400 available settings 103 setting time for sending meter report (voltage) the interval of sending meter report (voltage) to association device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled 5 2678400 available settings 104 setting time for sending meter report (current) the interval time of sending meter report (current) to associated device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled 5 2678400 available settings 254 enable/disable the configuration command lock/unlock all configuration parameters. 0 1 0 0 0 from to description 0 0 unlock 1 1 lock 1 over current protection smart plug keep detecting the load power, once the ac current exceeds 16 a for more than 5s, smart plug's relay will turn off. 0 1 0 0 1 from to description 0 0 the function is disabled 1 1 the function is enabled. 2 setting device status after power failure define how the plug reacts after the power supply is back on. 0 1 0 0 0 from to description 0 0 smart plug memorizes its state after a power failure. 1 1 connected device will be on after the power supply is reconnected. 2 2 connected device will be off after the power supply is reconnected. 3 notification when load status change smart plug can send notifications to associated device (group lifeline) when the status of smart plug’s load is changed. 0 1 0 0 1 from to description 0 0 the function is disabled. 1 1 send basic report. 2 2 send basic report only when load status is not changed by z wave command. 4 led load indicator mode selection configure led display mode to prevent light pollution at night. 0 1 0 0 0 from to description 0 0 the led status follows the load change. 1 1 when operating the load, the led lights for 5 seconds and then turns off. 17 the value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent when the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (group lifeline). 0 1 0 0 10 from to description 128 127 available setting 0 0 the function is disabled. texts