- Name
- Z-Wave 230V relay module
- Brand
- ABUS
- Features
- Feature Values Color
- Documents
- Category Description File Adv_Manual
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0702
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0005
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.01:00.01
- Library type
- SLAVE_ENHANCED_232
- Product line
- Performance Line
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.81.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0403
- Product type id
- 0x0003
- Long description
- The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home. Each relay can be turned on/off individually using Z-wave commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load. This unit is to be installed and sealed inside an electrical switch box.
- Hardware platform
- SD3502
- Short description
- The module is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. It supports two Inputs, to be wired to existing switches, and two outputs, to be wired to any 230V actuator, such as lighting.
- Product identifier
- PLHA10000
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-19116788
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported notification types
- Notification Type Event / State Appliance
- Value white firmware updatable value updatable by consumer by rf loads controlled value 2 neutral wire required switch load capacity watts value 1000 association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 3
- From to description 0 1 0: momentary button, 1: switch (toggle) 2 key 2 0: momentary button 1: switch (toggle) 1 1 0 1 0 from to description 0 1 0: momentary button, 1: switch (toggle) 3 relay 1 auto off time 0: no auto off 1 4 0 43200 0 from to description 0 43200 0: no auto off 4 relay 2 auto off time 0: no auto off 1 4 0 43200 0 from to description 0 43200 0: no auto off 5 remember relay 1 last state 0: do not remember 1: remember 1 1 0 1 1 from to description 0 1 0: do not remember, 1: remember 6 remember relay 2 last state 0: do not remember 1: remember 1 1 0 1 1 from to description 0 1 0: do not remember, 1: remember texts
- ID Description Value 8