- Name
- Power Manager
- Brand
- LG Uplus
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0007
- Device type
- On/Off Power Switch
- Oem version
- HW: 17 FW: 0.01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.61.00
- Frequency plans
- KR: 920.90MHz, 921.70MHz, 923.10MHz
- Manufacturer id
- 0x018C
- Product type id
- 0x0042
- Long description
- The device can remotely power on/off to the load connected and will inform you of the electricity usage of your load. You can use it to measure the power of the load connected to the device (currently instantaneous power & used power).
- Hardware platform
- ZM5101
- Short description
- The Z-Wave smart Power Strip makes it possible to meter the amount of power used by home appliance. This device can switch on or off the electric home appliance (remotely and manual)
- Product identifier
- MTD-01
- Countries / regions
- Republic of Korea
- Certification number
- ZC10-17015375
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by manufacturer representative switch load capacity current value 16 a switch load capacity volt ampere value 3600 va (220 v) switch load capacity watts value ~3600 w supported meter type value electric energy color value white association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 1 if value is 0, plug stop accumulating power value. if value is 1, plug start accumulating power value. 4 connected device use/not use this parameter is a value that indicates whether the device is in use connected to the plug. this is read only. and this parameter has meaning only when the standby power off function is on. value : 0 when connected device(home appliance) is not use value : 1 when connected device(home appliance) is in use before setting the standby power mode, this parameter is meaningless. only when using standby power break mode, plug can report this parameter. (this configuration value is used only 0 and 1.) 0 1 0 0 0 from to description 0 1 if value is 0, connected device is not use, if value is 1, it is in use. 1 standy power setting value this parameter determines whether to use the standby power cutoff function and determines the reference value of standby power cut off. if ther power consumption is less than the reference value, switch is turned off. this parameter value's size is 4 bytes. first 3 bytes is for setting standby power reference value. last 1 byte is for standby power monitoring function enable or disable. standby power setting value : 3 byte standby power enable/disble : 1 byte) standby power value example : if the value is set by 300(0x00012 c), standby power is 3.00w standby power function enable/disable example : if standby power is enable, value is 0x01. and, total 4 bytes is 0x00012 c01, ( default parameter value : 0 – 0.00 w, standby power disable) (max standby reference power is 600 w, 0x00 ea60) 0 4 0 0 0 from to description 0 60000 standby power reference value range(3 byte) 0 1 standby power monitoring function enable/disable setting value 2 peridic measurement value transmission this parameter determines whether or not to periodically reports the measured power values. value : 1 (transmits a power value measured at the plug, periodically. value : 0 (not transmitting power value) ( default : 1) 0 1 0 0 1 from to description 0 1 if value is 0, plug do not transmit power value. if value is 1, plug transmits power value to hub. 5 periodic time intervals this parameter is for the periodic report interval. minimum time interval : 10minutes(standard unit) value : 1 (10minutes * 1) = 10minutes interval value : 2 (10minutes * 2) = 20minutes interval …….. …….. value : 144(10m * 144) = 24 hours interval =>max ( default : 6 = one hour ) 0 1 0 0 6 from to description 1 144 unit is per 10 minutes.you can change this value using configuration command class. texts