- Name
- Smart Plug
- Brand
- LG Uplus
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0002
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 39.128
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.61.00
- Frequency plans
- KR: 920.90MHz, 921.70MHz, 923.10MHz
- Manufacturer id
- 0x0247
- Product type id
- 0x0042
- Long description
- Smart- Plug plugs in between any appliance and the AC outlet. It measures its power consumption & sends that information to your smartphone . It can also control power source connected with appliance manually and remotely using smartphone.
- Hardware platform
- ZM5101
- Short description
- Smart- Plug plugs in between any appliance and the AC outlet.
- Product identifier
- SPES - 02A
- Countries / regions
- Republic of Korea
- Certification number
- ZC10-17025438
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by professional/technician switch load capacity watts value 3500 supported meter type value electric energy switch type value push button association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 standby power disable 257 524033 standby power enable with 0.01 to 20.47 w standby 3 power accumulation mode power accumulation start/stop 0 1 0 0 1 from to description 0 0 power accumulation stop 1 1 power accumulation start 4 device usage connected device use / not use 0 1 0 0 0 from to description 1 1 connected device use 0 0 connected device not use 5 meter transmit interval periodic measurement value transmission interval minimum time interval : 10minutes value : 1 (10minutes * 1) = 10minutes interval value : 2 (10minutes * 2) = 20minutes interval …….. value : 127(10min * 72) = 720 minutes interval =>max 0 1 0 0 6 from to description 1 72 10min to 720 min 2 meter transmit periodic measurement value transmission enable/disable 0 1 0 0 1 from to description 1 1 periodic measurement value transmission enable 0 0 periodic measurement value transmission disable texts
- ID Description Value 2