- Name
- Smart Energy In Wall Meter
- Brand
- Philio
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- Energy Meters
- Product id
- 0x001A
- Device type
- Whole Home Meter - Simple
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0006
- Long description
- This dual meter module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. And it can act as repeaters within the network regardless of vendor to increase reliability of the network. Mini size design let the module can easily hide itself into the electricity distribution box and that will be good for the house decoration. This dual meter module is able to detect Instant power wattage (13800W/230Vac)(60 Amperes) of connected light or appliances.
- Hardware platform
- SD3502
- Short description
- This dual meter module is a transceiver which is a Z-WaveTM enabled device and it is able to detect Instant power wattage of connected light or appliances.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- PAB01-1
- Countries / regions
- European Union
- Certification number
- ZC10-16010004
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- From to description 1 32767 5*720s=3600s=1 hour 2 kwh meter report period if the setting is configured for 1hour (set value =720), the pab01 will report its accumulated power consumption (kw/h) every 1 hour to the node of correspond group. the maximum interval to report its accumulated power consumption (kw/h) is 45 hours (5s*32767/3600=45hr). 0 2 0 0 720 from to description 1 32767 5*720s=3600s=1 hour 3 selected endpoint if controller can't use multi channel command class to access the endpoint of pab01, you may configure the endpoint value to react the basic command class 、binary switch command class or meter command class v3. 0 1 0 0 3 from to description 1 1 1:ct1 2 2 2:ct2 3 3 3:ct1 and ct2 4 threshold of current for load caution this is a warning when the current of load over the preset threshold value, if the setting value is 6000, when the load wattage of ct1 or ct2 over 60 a, pab01 will send current meter report command to the node of correspond group. 0 2 0 0 6000 from to description 10 6000 6000*0.01 a=60 a 5 threshold of kwh for load caution this is a warning when the kwh of load over the preset threshold value, if the setting value is 10000, when the accumulated power consumption of ct1 or ct2 over this value, pab01 will send kwh meter report command to the node of correspond guoup, minum value is 1 kwh and default value is 10000 k wh. 0 2 0 0 10000 from to description 1 10000 10000*1 kwh=10000 kwh 6 existence of endpoint3 multi channel command is a good way to control relay1 and relay2 of pab01 individually. the endpoint3 of pab01 is related to both relay1 and relay2. in some condition it becomes redundant in multi channel command class. when the existence of endpoint3 is set as 2, the endpoint3 will be disabled. the default value is 1. endpoint1 and endpoint2 are fixed, only endpoint3 is dynamic. 0 1 0 0 1 from to description 1 1 1 : endpoint3 exist 2 2 2 : no endpoint3 texts