- Name
- S100 Socket iO
- Brand
- Simon
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0702
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0000
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 4.24:68.49
- Library type
- SLAVE_ENHANCED
- Supports nwi
- Yes
- Installer icon
- 0x0702
- Z wave version
- 6.51.07
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0267
- Product type id
- 0x0009
- Long description
- Socket iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of the socket and LEDs integrated. Available colors Black and White. visit http://www.simon.es/simon100/ to learn more about Simon 100 iO.
- Hardware platform
- ZM5202
- Short description
- Simon Socket iO is a socket that allows increase the installation functions and features.
- Product identifier
- 10002041-13X
- Countries / regions
- European Union
- Certification number
- ZC10-18026012
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 11
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by professional/technician neutral wire required supported meter type value electric energy switch type value toggle association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 time is disabled 1 127 time is set in seconds from 1 to 127 128 254 time is set in minutes from 1 to 127 17 post reset state sets the device state after a reset. 0 1 0 0 255 from to description 1 255 after a reset the load recovers the last value 0 0 after a reset the load starts off 1 association led activates the central led. configuration used by masters i o in order to identify the devices associated to their group2 during manual association process. 0 1 0 0 0 from to description 0 0 turns central led off 1 255 turns central led on 3 beacon sets the beacon intensity, turning on all device leds al percentage set in this configuration. 0 1 0 0 0 from to description 1 99 sets the intensity of the beacon leds 0 0 disables the beacon 1 limit power consumption limits the load power that can me connected to the socket in order to protect installation or global power consumption. 0 2 0 0 0 from to description 1 3680 limit power consumption to x watts 0 0 disables custom 10 delay on sets a delay from activation request until the activation is performed. this configuration must be set in hexadecimal values. 0x00 disables the delay. 0x01 to 0x7 f sets the delay in seconds from 1 to 127 0x80 to 0x ef sets the delay in minutes from 1 to 127 0 1 0 0 0 from to description 0 0 delay is disabled 1 127 sets the delay in seconds from 1 to 127 256 254 sets the delay in minutes from 1 to 127 texts
- ID Description Value 5