- Name
- Outlet
- Brand
- WINKA SYSIT
- Features
- Feature Values Supported Meter Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters
- Product id
- 0x1D61
- Device type
- On/Off Power Switch
- Oem version
- HW: 16 FW: 1.36
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.51.09
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0331
- Product type id
- 0x0003
- Long description
- This is a smart power plug, function includes Switch, Electrical parameters measure, Over-current protection & timing. Lets you wirelessly control whatever device is plugged into it remotely, from a schedule, or from the outlet iteself. This smart switch has electrical parameters measure, you can see the electricity which your device are using in real time from APP.
- Hardware platform
- ZM5202
- Short description
- Smart power plug with electrical parameters measure
- Product identifier
- WK-0003
- Countries / regions
- European Union
- Certification number
- ZC10-17105819
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 9
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value electric energy supported notification types value power management switch type value toggle association groups
- Group Number Maximum Nodes Supported End Point ID Description 3
- From to description 1 1600 the current changed value for meter report. (0.01 a) 1 outlet on/off state saved disable this parameter is set as '1'. the switch will save the current switch state, and after the outlet is powered down and restarted, it will automatically recover to the switch state before power down. 0 1 0 0 1 from to description 0 1 0 disable, 1 enable 6 meter reporting function disable setting this parameter as '0' will close the timed report function of the outlet, with no influence on the current change reporting function. the interval of reporting electric quantity detection result is controlled by the time set by parameter 7. 0 1 0 0 1 from to description 0 1 0 disable, 1 enable 2 button switch function disable setting this parameter as '0' will make it invalid to operate the outlet switch with the button 0 1 0 0 1 from to description 0 1 0 disable, 1 enable 4 timer enable setting this parameter as '1' will start the timing function of the outlet, and the length of time is determined by the setting of parameter 5.this function can only provide the timed closing control function when the outlet is open. 0 1 0 0 0 from to description 0 1 0 disable, 1 enable 5 time cycle setting this parameter sets the time length of closing the outlet at a fixed time, the unit of which is minute, which is only valid when parameter 4 is set as '1'. 0 2 0 0 150 from to description 1 32767 minute. the time interval for timer 3 outlet led indication disable setting this parameter as '0' will forbid the led of the outlet from being on; parameter '0' is invalid to the led indication in the power up state. 0 1 0 0 1 from to description 0 1 0 disable, 1 enable texts