- Name
- Heatit Z-Temp2
- Brand
- Heatit controls
- Features
- Feature Values Firmware Updatable
- Is flirs
- Yes
- Documents
- Category Description File Image_Product_Supplemental_3
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_LISTENING
- User icon
- 0x1200
- Categories
- Thermostats
- Product id
- 0x0204
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 1 FW: 1.01:00.02
- Library type
- SLAVE_ENHANCED_232
- Product line
- Thermostat
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 7.11.1
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x019B
- Product type id
- 0x0004
- Long description
- Heatit Z-Temp2 is a battery-operated thermostat designed for use with water based heating systems. Used in combination with the Heatit Z-Water regulator you can control your heating system with a Z-Wave primary controller/gateway with the use of Heatit Z-Water in combination with one or several Heatit Z-Temp2.
- Hardware platform
- EFR32Z
- Short description
- Heatit Z-Temp2 is a Z-Wave battery-operated thermostat for controlling external relays.
- Product identifier
- Z-Temp2
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-20050065
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 11
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Power Management
- Value updatable by manufacturer color value white battery quantity value 3 battery type value aa 1,5 v alkaline thermostat hvac systems supported value universal humidity control dual fuel thermostat power source value battery thermostat modes value heat association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 2
- From to description 50 400 5 to 40°c (default 50, 5°c) 3 humidity delta value humidity delta value. 1 2 0 50 10 from to description 0 0 reporting temperate based on change is disabled 5 50 5 to 50% (default 10, 10%) 2 temperature delta value temperature delta value. 1 2 0 50 10 from to description 0 0 reporting temperate based on change is disabled 5 50 0.5 to 5°c (default 10, 1.0°c) 5 humidity offset settings offsets the measured relative humidity. 1 2 100 100 0 from to description 100 100 10 to 10% (default 0, 0%) 4 temperature offset settings calibrate the internal sensor. 1 2 100 100 0 from to description 100 100 100 to 100°c (default 0, 0°c) 6 proximity sensor retrigger interval proximity sensor retrigger interval. 1 2 2 270 10 from to description 2 270 2 to 270 seconds (default 10, 10 seconds) 8 led maximum brightness adjust the backlight of lcd display. 1 2 0 99 50 from to description 0 99 0 to 99% (default 50, 50%) 7 proximity sensor – enable / disable choose if proximity sensor is used or not. 1 2 0 1 1 from to description 0 0 disable 1 1 enable (default) 9 led turned on before timeout adjust the time from proximity sensor / display touched until display goes to sleep. 1 2 3 300 3 from to description 3 300 3 to 300 secounds (default 3, 3 seconds). texts
- ID Description Value 8