- Name
- Heatit ZM Thermostat 16A
- Brand
- Heatit controls
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1201
- Categories
- Thermostats
- Product id
- 0x3502
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- Thermostat
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 7.15.4
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x019B
- Product type id
- 0x0004
- Long description
- Heatit ZM Thermostat is an electronic thermostat for electrical floor heating designed for in-wall installations. The thermostat allows you to control your electrical heating through your Z-Wave™ network. The module is equipped with a 16A single pole relay. The thermostat requires you to connect an external sensor which is included with the device. The device can withstand a max load of 16A at 230VAC.
- Hardware platform
- ZGM130
- Short description
- Heatit ZM Thermostat is an electronic thermostat for electrical floor heating designed for in-wall installations.
- Product identifier
- ZM Thermostat 16A
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-21100317
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by consumer by rf ip (ingress protection) rated neutral wire required outdoor use switch load capacity watts value 3600 thermostat hvac systems supported value heat only cool only thermostat modes value heat cool thermostat power source value mains powered (120 v/240 v) association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 1
- From to description 2 2 cooling, thermostat mode is in cooling mode 1 1 heating, thermostat mode is in heating mode 0 0 off, thermostat will not operate 3 minimum setpoint temperature decide the lowest setpoint temperature allowed by the thermostat 2 2 50 400 50 from to description 50 400 5,0°c to 40,0°c, set the minimum setpoint temperature for the thermostat 5 setpoint decide the thermostat setpoint 2 2 50 400 210 from to description 50 400 5,0°c to 40,0°c, set the setpoint temperature for the thermostat 4 maximum setpoint temperature decide the highest setpoint temperature allowed by the thermostat 2 2 50 400 400 from to description 50 400 5,0°c to 40,0°c, set the maximum setpoint temperature for the thermostat 6 sensor calibration manually calibrate the sensor ±6°c 1 1 60 60 0 from to description 60 60 6,0°c to 6,0°c calibrate the sensor ±6°c nb! to set a negative value, use 256 and subtract the desired value 8 temperature report hysteresis temperature reports based on change in temperature from last report 2 1 0 100 10 from to description 0 0 temperature report based on delta value is disabled. 1 100 0,1°c to 10°c 10 inverted output decides if the relay output should be inverted 2 1 0 1 0 from to description 0 0 standard output 1 1 inverted output texts
- ID Description Value 5