- Name
- Heatit Z-TRM3
- Brand
- Heatit controls
- Features
- Feature Values IP (Ingress Protection) Rated
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1201
- Categories
- Thermostats
- Product id
- 0x0203
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 3 FW: 4.00:04.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- Heatit Climate Control
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 6.81.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x019B
- Product type id
- 0x0003
- Long description
- Heatit Z-TRM3 is an electronic thermostat for electrical floor heating, designed to be mounted in a standard flush box. The thermostat has a built-in Z-Wave chip that can be connected with Home Automation systems. Heatit Z-TRM3 has SmartStart. This feature allows the user to include all devices with SmartStart by scanning the QR codes on the devices. On startup all the devices will automatically be included in the gateway (requires SmartStart compability). This saves the installer a lot of work. Heatit Z-TRM3 is equipped with a single pole switch and fits into System 55 frames. The thermostat can withstand a load of max 16A /3600W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors. The thermostat has the capacity of up to 5 associations (relays, wall plugs etc.). The thermostat is designed for electrical heating. It may be used for waterbased heating if the thermostat is linked with the Heatit Z-Water.
- Hardware platform
- ZM5101
- Short description
- Heatit Z-TRM3 is an electronic thermostat for electrical floor heating, designed to be mounted in a standard flush box. The thermostat has a built-in Z-Wave chip that can be connected with Home Automation systems. Heatit Z-TRM3 has SmartStart.
- Product identifier
- Z-TRM3
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-20036889
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 11
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value dry contact thermostat hvac systems supported value simple relay thermostat modes value heat thermostat power source value mains powered (120 v/240 v) color value white neutral wire required firmware updatable value updatable by consumer by rf switch load capacity volt ampere value 3600 switch load capacity watts value 3600 electric load type value incandescent fluorescent mlv (magnetic) elv (electronic) led dimmable led inductive (e.g. motor) dimmable fluorescent dimmable mlv (magnetic) dimmable elv (magnetic) association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- From to description 60 60 6.0°c to 6.0°c. default is 0 (0.0°c) 7 air (a2) minimum temperature limit (alo) air (a2) minimum temperature limit (alo) 2 2 50 400 50 from to description 50 400 5.0°c to 40.0°c. default is 50 (5.0°c) 17 display brightness – active state display brightness – active state. configure the brightness of the display, in active state. 2 1 0 100 100 from to description 0 100 0 to 100% (default 100%) 2 sensor mode sensor mode 2 1 0 4 1 from to description 0 0 f mode, floor sensor mode 1 1 a mode, internal room sensor mode (default) 2 2 af mode, internal room sensor with floor limitation 3 3 a2 mode, external room sensor mode 4 4 a2 f mode, external sensor with floor limitation 3 floor sensor type floor sensor type 2 1 0 5 0 from to description 0 0 10 k ntc (default) 1 1 12 k ntc 2 2 15 k ntc 3 3 22 k ntc 4 4 33 k ntc 5 5 47 k ntc 1 operation mode operation mode 2 1 0 1 1 from to description 0 0 off 1 1 heating mode (default) 5 floor minimum temperature limit (flo) floor minimum temperature limit (flo) 2 2 50 400 50 from to description 50 400 5.0°c to 40.0°c. default is 50 (5.0°c) 6 floor maximum temperature limit (fhi) floor maximum temperature limit (fhi) 2 2 50 400 400 from to description 50 400 5.0°c to 40.0°c. default is 400 (40.0°c) 8 air (a2) maximum temperature limit (ahi) air (a2) maximum temperature limit (ahi) 2 2 50 400 400 from to description 50 400 5.0°c to 40.0°c. default is 400 (40.0°c) 9 heating mode setpoint heating mode setpoint 2 2 50 400 210 from to description 50 400 5.0°c to 40.0°c. default is 210 (21.0°c) 10 room sensor calibration (a) room sensor calibration (a) nb. to set a negative value, use 256 and subtract the desired value. 1 1 60 60 0 from to description 60 60 6.0°c to 6.0°c. default is 0 (0.0°c) texts