- Name
- Radio Socket
- Brand
- myTEM SmartHome
- Features
- Feature Values Sensors
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0701
- Categories
- Sensors, Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0004
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0701
- Z wave version
- 6.71.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x034E
- Product type id
- 0x0001
- Long description
- The myTEM Radio Socket is a universal, Z-Wave compatible switch/adapter for loads up to 3'600 watts (type F, EU). The power and energy consumption of the connected device is measured. In addition, a temperature and humidity sensor is integrated. These values are reported to the central controller and can be used to control other functions.
- Hardware platform
- ZM5101
- Short description
- The myTEM Radio Socket is a universal Z-Wave compatible adapter for loads up to 3'600 watts.
- Product identifier
- MTSOC-100-WL
- Countries / regions
- European Union
- Certification number
- ZC10-19056472
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 10
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value air temperature humidity switch load capacity volt ampere value 3600 electric load type value incandescent elv (electronic) inductive (e.g. motor) supported meter type value electric energy switch load capacity watts value 3600 firmware updatable value updatable by consumer by rf supported notification types value power management system association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 120 send interval humidity [min] 2 main voltage the main voltage is used together with the phase shift parameter and the messured current to calculate the actual power of the output and the cumulated energy. 0 2 80 280 230 from to description 80 280 main voltage [v] 3 phase shift cosines (phi) the phase shift is used together with the main voltage parameter and the messured current to calculate the actual power of the output and the cumulated energy. 0 2 0 100 100 from to description 0 100 phase shift [0.01%] 4 send interval power if the power value of the output does not change, the meter report for the actual power is sent after the send interval power. 0 2 1 120 5 from to description 1 120 send interval power [min] 5 minimum delta power send whenever the calculated power has changed by the minimum delta power send value since the last value sent, the actual power is sent by a meter report. 0 2 1 100 5 from to description 1 100 minimum delta power [%] 8 send interval temperature if the temperature value does not change, the multilevel sensor report with the actual temperature is sent after the send interval temperature 0 2 1 120 5 from to description 1 120 send interval temperature [min] 1 heartbeat rate if the notification system heartbeat is on, a notification report system heartbeat is sent periodically every 60 minutes (default value). 0 2 1 1440 60 from to description 1 1440 heartbeat rate [min] 6 send interval energy if the cumulated energy value does not change, the meter report for the cumulated energy is sent after the send interval energy. 0 2 1 120 5 from to description 1 120 send interval energy [min] 11 minimum delta humidity send whenever the measured humidity has changed by the minimum delta humidity send value since the last value sent, the actual humidity is sent by a multilevel sensor report. 0 2 10 1000 50 from to description 10 1000 minimum delta humidity [0.1 %] 9 minimum delta temperature send whenever the measured temperature has changed by the minimum delta temperature send value since the last value sent, the actual temperature is sent by multilevel sensor report. 0 2 1 100 5 from to description 1 100 minimum delta temperature [0.1 k] 7 minimum delta energy send whenever the cumulated energy has changed by the minimum delta energy send value since the last value sent, the cumulated energy is sent by a meter report. 1 2 1 50000 2000 from to description 1 50000 minimum delta energy [0.001 k wh] texts