- Name
- Radio Switch Dual
- Brand
- myTEM SmartHome
- Features
- Feature Values Loads Controlled
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0704
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0007
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0704
- Z wave version
- 6.71.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x034E
- Product type id
- 0x0001
- Long description
- The myTEM Radio Switch Dual is a universal, Z-Wave compatible wall or ceiling switch (ON/OFF) and is used to control two electrical devices (e.g. roller shutters, window blinds, lamps, fans, etc.). The power and energy con-sumption of the connected devices are measured. Two additional digital inputs and the programmable be-havior to the wireless commands allow flexible use in the house. At the same time, the device also serves as a Z-Wave repeater to improve range and stability of the Z-Wave network. The device is intended for installation in a flush-mounted box, e.g. behind light switches or sockets.
- Hardware platform
- ZM5101
- Short description
- The myTEM Radio Switch Dual is a universal, Z-Wave compatible wall or ceiling switch (ON/OFF) and is used to control two electrical devices. The power and energy con-sumption of the connected devices are measured. Two additional digital inputs and the programmable be-havior to the wireless commands allow flexible use in the house.
- Product identifier
- MTSWI-100-WL
- Countries / regions
- European Union
- Certification number
- ZC10-19086712
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 8
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_BINARY
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value 2 firmware updatable value updatable by consumer by rf supported meter type value electric energy supported notification types value power management system switch load capacity current value 6 switch load capacity volt ampere value 1380 electric load type value incandescent elv (electronic) inductive (e.g. motor) switch load capacity watts value 1380 association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 120 interval energy [min] 7 minimum delta power send output 1 when the power of output 1 changes this anount the energy value is sent by a meter report. 0 2 1 100 5 from to description 1 100 minimum dleta power [%] 3 phase shift cosines (phi) together with the mesured current and the main voltage configuration parameter the phase shift configruation parameter is used to calculate the power of the oututs. 0 2 0 100 100 from to description 0 100 phase shift [0.01] 10 send interval power output 2 period with which the power of output 2 is sent by a meter report. 0 2 1 120 5 from to description 1 120 interval power [min] 9 minimum delta energy output 2 when the energy of output 2 changes this anount the energy value is sent by a meter report. 1 2 1 50000 2000 from to description 1 50000 minimum delta energy [0.001 k wh] 4 send interval energy output 1 period with which the energy of output 1 is sent by a meter report. 0 2 1 120 5 from to description 1 120 interval energy [min] 6 send interval power output 1 period with which the power of output 1 is sent by a meter report. 0 2 1 120 5 from to description 1 120 interval power [min] 11 minimum delta power send output 2 when the power of output 2 changes this anount the energy value is sent by a meter report. 0 2 1 100 5 from to description 1 100 minimum delta power [%] 5 minimum delta energy send output 1 when the energy of output 1 changes this anount the energy value is sent by a meter report. 1 2 1 50000 2000 from to description 1 50000 minimum delta energy [0.001 k wh] 1 heartbeat rate if the notification system heartbeat is on, a notification report system heartbeat is sent periodically every 60 minutes (default value). 0 2 1 1440 60 from to description 1 1440 heartbeat rate [min] texts