- Name
- Radio Switch Shutter Plus
- Brand
- myTEM SmartHome
- Features
- Feature Values Electric Load Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1900
- Categories
- Sensors, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x000C
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Window Covering - Endpoint Aware
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- myTEM SmartHome.
- Supports nwi
- Yes
- Installer icon
- 0x1900
- Z wave version
- 6.82.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x034E
- Product type id
- 0x0001
- Long description
- The myTEM Radio Switch Shutter Plus is a universal, Z-Wave compatible wall or ceiling switch and is used to control the motor of blinds, Venetian blinds, roller shutters, awnings, etc. These are controlled via a myTEM Radio Server, via switches or buttons connected to the inputs or via the optional myTEM Touch Add-on, which can be connected to the rear socket. The device is intended for installation in a flush-mounted box.
- Hardware platform
- ZM5101
- Short description
- The myTEM Radio Switch Shutter Plus is a universal, Z-Wave compatible wall or ceiling switch and is used to control the motor of blinds, Venetian blinds, roller shutters, awnings, etc.
- Product identifier
- MTSWIS-101-WL
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-21027009
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values Read-only 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported notification types
- Notification Type Event / State Power Management
- Value inductive (e.g. motor) switch load capacity current value 2x 6 a, 250 vac or 30 vdc firmware updatable value updatable by consumer by rf supported notification types value power management system z wave scene type value central scene association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- From to description 0 500 slat move time [0.01s] 2 full distance down drive time time the blind uses to drive from upper end position to the lower end position. 2 2 0 30000 0 from to description 0 30000 full distance down drive time [0.01s] yes 5 start position calibration start a positioning calibration. used to start to measure time used by blind to move from one end position to the other. 2 2 0 1 0 from to description 1 1 start position calibration / position calibration is active 0 0 position calibration is inactive / has ended 8 key assignment local control digital inputs and touch add on may be used to control blinds locally. different key pairs can be assigned to control blind to move up or down resp. 2 2 0 6 0 from to description 1 1 input 1 > up, input 2 > down 2 2 input 1 > down, input 2 > up 3 3 touch 2 > up, touch 4 > down 4 4 touch 3 > up, touch 5 > down 5 5 touch 2 > left, touch 3 > right 6 6 touch 4 > left, touch 5 > right 0 0 locol control of blinds disabled 6 invert outputs normaly output 1 is used to drive blind upwards and output 2 to drive it downwards. when parameter is set to 1 output 1 drives blind downwards and output 2 upwards. 2 2 0 1 0 from to description 1 1 inverted assignment of outputs 0 0 normal assignment of outputs 7 min off time of outputs when blind should change direction while running, the time defined in this parameter is used between stopping active direction output and starting oposite direction output. 2 2 10 50 10 from to description 10 50 minimum off time of one output before turning on other one [0.01s] 1 heartbeat rate a heartbeat notification is sent at this rate 2 2 1 1440 60 from to description 1 1440 heartbeat rate [min] 3 full distance up drive time time the blind uses to drive from lower end position to the upper end position. 2 2 0 30000 0 from to description 0 30000 full distance up drive time [0.01s] yes texts